MODEL | 6503 | 6505 | 6510 | 6520 | 6530 | 6540 | 6560 |
INPUT |
Phase | 1ø | 3ø |
Voltage | 230Vac±15% | 220/380Vac±10% |
Frequency | 47-63Hz |
OUTPUT |
Max. Power | 3KVA | 5KVA | 10KVA | 20KVA | 30KVA | 40KVA | 60KVA |
Max. Current (r.m.s) *1 | 0-150V | 25.2A | 42.0A | 84.0A | 168.0A | 252.0A | 336.0A | 504.0A |
0-300V | 12.6A | 21.0A | 42.0A | 84.0A | 126.0A | 168.0A | 252.0A |
Max. Current (r.m.s) (Option 0-600V) *2 | 0-300V | 12.6A | 21.0A | 42.0A | 84.0A | 126.0A | 168.0A | 252.0A |
0-600V | 6.3A | 10.5A | 21.0A | 42.0A | 63.0A | 84.0A | 126.0A |
Phase | 1ø/2W |
Total Harmonic Distortion (T.H.D) | < 1% at 47-63Hz (Resistive Load) |
Crest Factor | >3 |
Line Regulation | ± 0.1V |
Load Regulation | ± (0.5% of output +0.5V) at Resistive Load |
Response Time | < 2 msec |
SETTINGS |
Voltage | Range | 0-150V/0-300V Selectable or 0-300V/0-600V Selectable(Option 0-600V) |
Resolution | 0.1V |
Accuracy | ±(1% of setting + 2counts) |
Frequency | Range | 47.0-63.0Hz Full Range Adjust |
Resolution | 0.1Hz |
Accuracy | ±0.02% of setting |
MEASUREMENT |
Voltage | Range | 0.0-300.0V / 0.0-600.0V(Option 0-600V) |
Resolution | 0.1V |
Accuracy | ± (1% of reading + 2counts) for 0-300V / ± (1% of reading + 4counts) for 0-600V |
Frequency | Range | 47.0-63.0Hz |
Resolution | 0.1Hz |
Accuracy | ±0.1Hz |
Current (r.m.s) | Range | L | 0.000-3.500A | 0.00-35.00A | 0.0 - 350.0A |
H | 3.00-35.00A | 30.00-350.0A | 300 - 3500A |
Resolution | L | 0.001A | 0.01A | 0.1A |
H | 0.01A | 0.1A | 1A |
Accuracy | L | ± (1% of reading +5counts) | ± (1% of reading +2counts) | ± (1% of reading +2counts) |
H | ± (1% of reading +1count) | ± (1% of reading +1count) |
Current (r.m.s) (Option 0-600V) | Range | L | 0.000-3.500A | 0.00-35.00A |
H | 3.00-35.00A | 30.00-350.0A |
Resolution | L | 0.001A | 0.01A |
H | 0.01A | 0.1A |
Accuracy | L | ± (1% of reading +5counts) | ± (1% of reading +2counts) |
H | ± (1% of reading +1count) | ± (1% of reading +1count) |
Power | Range | L | 0.0-350.0W | 0.000-3.500KW | 0.00-35.00KW |
H | 300-4000W | 3.00-40.00KW | 30.0-350.0KW |
Resolution | L | 0.1W | 0.001KW | 0.01KW |
H | 1W | 0.01KW | 0.1KW |
Accuracy | L | ± (1.5% of reading +5counts) |
H | ± (1.5% of reading +1count) |
Power Factor | Range | 0.000-1.000 |
Resolution | 0.001 |
Accuracy | W / V x A , Calculated and displayed to three significant digits |
GENERAL |
PLC Remote | I/P:ON/OFF, P1, P2, P3, O/P:Processing |
Memory | 8 Memoies, 5steps per memory for Voltage, Frequency, Test Time, Delay time and Current, Power, Power Factor Hi, Lo Limit setting. |
Timer | 0=Continuous, 1-9999 (Unit: sec, minute, hour selectable) |
Auto Loop Cycle | 0=Continuous, OFF=Loop Once, 2~9999 (Unit:×1, ×10, ×100) |
Auto Voltage Adjust | Enable it for improve voltage regulation within ±0.1V |
Efficiency | ≧80%(at Full Load ) | ≧85%(at Full Load ) |
Protection | Over Load , Short Circuit , Over Temperature |
Calibration | Front Panel Calibration |
Interface (Option) | GPIB/RS232 |
Environment | 0-40℃/20-80%RH |
Dimension (W×H×D) mm | 430×222×650 | 430×222×650 | 430×489×650 | 430×756×650 | 600×978×900 | 600×978×900 | 800×1245×900 |
Dimension with Caster (W×H×D) mm | 430×306×650 | 430×306×650 | 430×573×650 | 430×863×650 | 600×1085×900 | 600×1085×900 | 800×1390×900 |
Dimension (W×H×D) mm (PFC) | 430×489×650 | 430×489×650 | 430×622×650 | 430×756×650 | 600×978×900 | 600×978×900 | 800×1245×900 |
Dimension with Caster (W×H×D) mm (PFC) | 430×573×650 | 430×573×650 | 430×729×650 | 430×863×650 | 600×1085×900 | 600×1085×900 | 800×1390×900 |
Net Weight | 47Kg | 69Kg | 150Kg | 216Kg | 372Kg | 402Kg | 487Kg |
Net Weight (PFC) | 83Kg | 119Kg | 226Kg | 346Kg | 536Kg | 600Kg | 760Kg |